Myanmar steam boiler damper

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • BOILER CONTROLS &BOILER CONTROLS &

    2010-11-15 · cylinder of the id fan damper to open orcylinder of the id fan damper to open or close the same and thus controls the ... technologies private limitedlimited 15. combustion control the steam demand from boiler varythe steam demand from boiler vary depending upon change in process requirement or power requirement. the fuel fed to the boiler ...

    Get Price
  • Boiler Efficiency and Combustion

    Boiler Efficiency and Combustion. A broad overview of the combustion process, including burner types and controls, and heat output and losses. This Module is intended to give a very broad overview of the combustion process, which is an essential component of overall boiler efficiency. Readers requiring a more in-depth knowledge are directed ...

    Get Price
  • INSTRUCTION MANUAL - Rite Boiler

    2020-6-28 · 1. If the boiler is temporarily stored outdoors it must be completely protected from moisture by a tarp or other means. 2. Keep the Draft Diverter, Barometric Damper and any other equipment shipped loose with the boiler, other-wise they may become lost. STORAGE PLACEMENT. 5. When installing on a concrete pad be, sure the pad is big enough in ...

    Get Price
  • Steam Boiler Controls - InspectAPedia

    and steam boilers (discussed here at STEAM HEATING SYSTEMS) use a boiler that heats water, the heat distribution method and most of the heating boiler controls are different between these two systems. Both steam boilers and hot water boilers may …

    Get Price
  • Damper Regulator For Steam Boiler - chestofbooks.com

    The damper regulator used on a steam boiler is a simple device that automatically controls the draft dampers by reason of the changing pressures of the steam. The object of the damper regulator is to prevent the generation of steam in the boiler beyond a …

    Get Price
  • Industrial Steam Boiler Manufacturers Myanmar -

    2020-11-6 · ZOZEN boiler was established in 1988, is a professional industrial steam boiler manufacturers, more than 30 years of production technology for precipitation, over 60 has applied patent technology, boiler products in 100 countries and regions, run …

    Get Price
  • How to Install a Boiler Vent Damper

    2010-2-16 · Step 3 - Measuring the Duct. Measure the size of the duct so that you will be able to choose a vent damper that will be a good enough fit. You will not get enough control out of a loose-fitting vent damper because air will escape around the gaps between the fans and the damper. If you are interested in temperature control, find a boiler vent ...

    Get Price
  • Williamson Thermoflu GSA-250 Gas Steam Atmospheric

    'Uncover warm possibilities' with Williamson-Thermoflo's GSA gas fired steam boiler. The highly efficient GSA-250-N-IP pumps out 250,000 BTUs with an AFUE (annual fuel utilization efficiency) rating of 83.0 percent. The GSA is also designed with a generous heating surface and an automatic vent damper to maintain that efficiency.

    Get Price
  • damper in steam boiler – Industrial Boiler Supplier

    2017-11-17 · damper in steam boiler. damper in steam boiler. Posted On : 2017-11-17 Published By : Jenny Wu. Quick inquiry: I need the quotation of , the fuel is , the capacity is . My Name is , My Email is , My phone number is , Please Send the ...

    Get Price
  • Williamson GSA-200-NIP 200,000 BTU Natural Gas Steam ...

    'Uncover warm possibilities' with Williamson-Thermoflo's GSA gas fired steam boiler. The highly efficient GSA-200-N-IP pumps out 200,000 BTUs with an AFUE (annual fuel utilization efficiency) rating of 82.8 percent. The GSA is also designed with a generous heating surface and an automatic vent damper to maintain that efficiency. .

    Get Price
  • GAS VENT DAMPER - Field Controls

    2019-6-27 · Vent Damper. The damper is installed in the vent as close to the draft hood as practical. When properly in-stalled, the damper opens before the burner fires, and closes after the burner shuts off. The electrical circuits in this product are designed not to override the existing limit and safety controls of the boiler.

    Get Price
  • BOILER CONTROLS &BOILER CONTROLS &

    2010-11-15 · cylinder of the id fan damper to open orcylinder of the id fan damper to open or close the same and thus controls the ... technologies private limitedlimited 15. combustion control the steam demand from boiler varythe steam demand from boiler vary depending upon change in process requirement or power requirement. the fuel fed to the boiler ...

    Get Price
  • INSTALLATION, OPERATING AND SERVICE

    2015-10-14 · Mount the vent damper on the flue collar without modification to either and secure with sheet metal screws. Make sure screws do not interfere with damper blade operation. Vent damper blade position indicator must be visible to users. c) The damper wire harness is shipped wired into the boiler junction box. Plug the loose end of this harness ...

    Get Price
  • BOILER (BABCOCK & WILCOX BOILER

    2017-2-22 · The Babcock and Wilcox Boiler consists of 1. Steam and water drum (boiler shell) 2. Water tubes 3. Uptake-header and down corner 4. Grate 5. Furnace 6. Baffles 7. Super heater 8. Mud box 9. Inspection door 10. Damper Steam and water drum (boiler shell): One half of the drum which is horizontal is filled up with water and steam remains on the ...

    Get Price
  • Pneumatic Vane Damper Drives for Boiler Flue Gas and ...

    2021-7-26 · Pneumatic damper drives are excellent alternatives to electric drives because of speed, accuracy, and reliability. Pneumatic vane damper drives don't have gears or motor windings that slow down response or introduce slop. Pneumatic vane drives …

    Get Price
  • Procidia Control Solutions Boiler Control Overview

    2015-1-23 · The boiler control system manipulates the firing rate so that the supply of steam remains in balance with the demand for steam over the full load range. In addition, an adequate supply of feedwater must be maintained, as must the correct air/fuel mixture for safe, economical combustion. In the following sections, boiler control subsystems

    Get Price
  • INSTRUCTION MANUAL - Rite Boiler

    2020-6-28 · 1. If the boiler is temporarily stored outdoors it must be completely protected from moisture by a tarp or other means. 2. Keep the Draft Diverter, Barometric Damper and any other equipment shipped loose with the boiler, other-wise they may become lost. STORAGE PLACEMENT. 5. When installing on a concrete pad be, sure the pad is big enough in ...

    Get Price
  • INSTALLATION, OPERATION & MAINTENANCE MANUAL

    2000-8-21 · Utica Boilers. 2201 Dwyer Ave Utica, NY 13501. www.ecrinternational.com. PEG-C. GAS FIRED BOILERS FOR STEAM HEATING. INSTALLATION, OPERATION & MAINTENANCE MANUAL. An ISO 9001-2008 Certified Company. H

    Get Price
  • What is a Barometric Damper? - heatinghelp.com

    2015-8-13 · The barometric damper is used to control the draft inside a boiler. It is installed on boilers that use a Category I vent. To understand how the barometric damper operates, we need to understand what draft is. We all know that when air is heated, it will rise. Hot …

    Get Price
  • How to Install a Boiler Vent Damper

    2010-2-16 · Step 3 - Measuring the Duct. Measure the size of the duct so that you will be able to choose a vent damper that will be a good enough fit. You will not get enough control out of a loose-fitting vent damper because air will escape around the gaps between the fans and the damper. If you are interested in temperature control, find a boiler vent ...

    Get Price
  • Boiler Damper Manufacturer,Supplier,Exporter & Service ...

    Buy Boiler Damper at best price. Started in2007, we are trusted manufacturer of high quality Boiler Damper and other machinery from Pune, India.

    Get Price
  • The damper in a steam boiler is provided to control the ...

    The damper in a steam boiler is provided to control the draught (i.e. rate of flow of air) and thus regulate the rate of generation of steam. Correct Incorrect

    Get Price
  • Stack damper for residential steam boiler ...

    2019-3-1 · Stack damper for residential steam boiler kjmass1 | Posted in General Questions on March 1, 2019 03:49pm I’m working on getting my basement insulated and airsealed, but on top of that I was wondering if I should consider an automatic stack damper for my 1970s era oversized 200k natural gas steam boiler.

    Get Price
  • Better damper control delivers big savings

    2004-11-1 · About a year ago, a vintage 1980 pneumatic damper actuator on a steam boiler at Equistar Chemical’;s Corpus Christi, Texas, plant was replaced with a state-of-the-art Contrac electric drive from ABB Inc., Warminster, Pa. Electric drives, also known as actuators, must position combustion air dampers on steam boilers precisely and reliably.

    Get Price
  • Secondary Air Damper Control in Boiler

    2021-7-23 · Secondary Air Damper Control in Boiler. Keywords: furnace to windbox differential pressure, windbox to furnace In this proposed work, design and development of controlling Secondary air dampers in a draft system of a power plant which is presently working on DCS technique has been accomplished by using high computing software ARDUINO and results has been shown with suitable simulation in ...

    Get Price
  • The Basics of Boiler Safety – Technology Transfer Services

    The Basics of Boiler Safety. The Basics of Boiler Safety. In 1905, the Grover Shoe Factory boiler exploded, collapsing the building and engulfing it in flames. Fifty-eight people were killed and 150 more injured. This event led to the development of safety laws and a national code for the safe operation of steam boilers.

    Get Price
  • Boiler Firing Controls Functional Specification ...

    The header also receives steam that is generated in process units as well as in parallel boilers. Steam demand and supply can change suddenly, depending upon operating conditions and upsets anywhere in the steam system. Therefore, the boiler must have effective process controls that set fuel firing to match the changing demand for steam.

    Get Price
  • Galaxy GG, GX, GXH & GXHA Series, Sentry S/SX Series

    2020-4-29 · If your boiler is purchased with or will be equipped with an automatic vent damper, make certain that the damper is installed and wired by a qualified installer who has been certified by your local gas utility. See Vent Dampers page 7. Keep the boiler area clean and free of all materials that can burn.

    Get Price
  • Dual End Buckling Restrained Damper Braces

    2021-8-20 · The effect of damper braces depends on the structures to which the damper braces are applied. For instance, when the damper braces are applied to boiler support structures, a common steel structure in thermal power plants, it is possible to reduce 30 to 50% of shear forces in the structure.

    Get Price
  • Application Note: Flue Gas Analysis as a Boiler Diagnostic ...

    2020-3-28 · making fan or damper adjustments small enough to control at these low levels is difficult. Many operators will make manual adjustments based upon the CO signal, or use the measurement as a feed forward signal to adjust the O 2 control setpoint upwards or downwards. 16 Original Setpoint New Setpoint Actual Data % Excess O 2 % Steam Flow 14 12 10 ...

    Get Price
  • Steam Injectors for boilers

    Steam injectors are used to inject live steam into feedtanks to drive off the dissolved oxygen. Considerably reducing the amount of oxygen scavenging chemicals required. Maintaining high and consistent feedwater temperature to the steam boiler.

    Get Price
  • Clayton Low NOx Burner Systems - Industrial Steam Boilers ...

    The premix chamber on the E-series steam boilers is a rectangular duct with a gas diffusion pipe and mixing plates. Mounted between the main blower and premix chamber is a modulating air damper. The outlet of the premix chamber is connected to the inlet volute that directs the premixed air/fuel to the “Fiber Metal” burner assembly.

    Get Price
  • Secondary Air Damper Control in Boiler

    2021-7-23 · Secondary Air Damper Control in Boiler. Keywords: furnace to windbox differential pressure, windbox to furnace In this proposed work, design and development of controlling Secondary air dampers in a draft system of a power plant which is presently working on DCS technique has been accomplished by using high computing software ARDUINO and results has been shown with suitable simulation in ...

    Get Price
  • STEAM BOILERS - Slantfin

    2020-4-29 · LOW PRESSURE STEAM—Models GXH-230 through GXH-300H LOW PRESSURE STEAM—Models GXHA-100 through GXHA-200 GALAXY GAS-FIRED CAST IRON BOILERS FOR NATURAL AND L.P. PROPANE GASES ™ STEAM BOILERS Heating Contractor Address Phone Number Boiler Model Number Boiler Serial Number Installation Date WARNING SEE “WARNING” ON …

    Get Price
  • Damper drives for boilers - esmagazine.com

    2010-1-28 · Highly illustrated eight-page color brochure from ABB Instrumentation covers damper drive solutions for improved boiler control. According to the brochure, the average power plant has hundreds of actuators controlling airflow and other process variables to maximize the combustion process and minimize emissions.

    Get Price
  • smoke stack damper for hot water heating boiler

    2021-3-17 · Steam boilers and flue dampers A flue damper is incredibly useful when you have a steam boiler i. Learn More. Automatic Stack Dampers - Rite Boilers. Rite Boilers can provide automatic stack dampers for all our atmospheric fired boilers. In addition to keeping the heat inside the boiler as the burner cycles on and off during normal operation ...

    Get Price
  • Stack damper for residential steam boiler ...

    2019-3-1 · Stack damper for residential steam boiler kjmass1 | Posted in General Questions on March 1, 2019 03:49pm I’m working on getting my basement insulated and airsealed, but on top of that I was wondering if I should consider an automatic stack damper for my 1970s era oversized 200k natural gas steam boiler.

    Get Price
  • PROCESS DESIGN OF STEAM BOILERS (PROJECT

    2016-3-6 · l. Steam drum and boiler tube system maximum design temperature specified on data sheet, superheater design temperature per code. m. Total continuous and intermittent blowdowns shall not be more than allowable figure specified in the boiler data sheet of steam generated, Vendor to specify capacity at 100% rating. n.

    Get Price
  • Application Note: Flue Gas Analysis as a Boiler Diagnostic ...

    2020-3-28 · making fan or damper adjustments small enough to control at these low levels is difficult. Many operators will make manual adjustments based upon the CO signal, or use the measurement as a feed forward signal to adjust the O 2 control setpoint upwards or downwards. 16 Original Setpoint New Setpoint Actual Data % Excess O 2 % Steam Flow 14 12 10 ...

    Get Price
  • Steam Boiler Controls - InspectAPedia

    and steam boilers (discussed here at STEAM HEATING SYSTEMS) use a boiler that heats water, the heat distribution method and most of the heating boiler controls are different between these two systems. Both steam boilers and hot water boilers may …

    Get Price
  • Level Controls for steam boilers

    A level control system consists of a sensor, controller, valve or pump and may be on-off or modulating. It is vital that your boiler water levels be monitored safely and accurately. Products compliant with all relevant European standards and regulations. Safe working environment for your employees. Reduce the risk of accidents in the boiler house.

    Get Price
  • Steam Injectors for boilers

    Steam injectors are used to inject live steam into feedtanks to drive off the dissolved oxygen. Considerably reducing the amount of oxygen scavenging chemicals required. Maintaining high and consistent feedwater temperature to the steam boiler.

    Get Price
  • Industrial Boiler for Myanmar,Steam Boiler,Hot Water Boiler

    2021-8-20 · WNS oil and gas fired boiler. WNS series oil and gas fired boiler is one of the key export products of our company, can be widely used in production, power generation, heating, hot water supply and other fields. The measured NOx emission concentration is far below 30mg/m3. Capacity : 1-20Ton/1.4-14MW. Pressure ≤1.6MPa.

    Get Price
  • Y5 11 Boiler Coupling Centrifugal Blower Fan

    gas steam boiler,condensing boiler,condensing steam . For Sale 2t biomass boiler Industrial Myanmar. Myanmar gas fired steam boiler price or cost. 3t/h Biomass fired steam Boiler in Myanmar 3t/h Biomass fired steam Boiler in Myanmar. cost for manufacturer 6t waste wood steam boiler for maufacturer 8t fire tube boiler for manufacturer 8tongas ...

    Get Price
  • Clayton Low NOx Burner Systems - Industrial Steam Boilers ...

    The premix chamber on the E-series steam boilers is a rectangular duct with a gas diffusion pipe and mixing plates. Mounted between the main blower and premix chamber is a modulating air damper. The outlet of the premix chamber is connected to the inlet volute that directs the premixed air/fuel to the “Fiber Metal” burner assembly.

    Get Price
  • Boiler Cleaning Technology - Babcock & Wilcox

    B&W Diamond Power boiler cleaning systems are available in steam/air, high pressure water, and dual-media air heater cleaning configurations. With more than a century of experience in boiler cleaning, you can depend on low maintenance, reliability, …

    Get Price
  • Large damper for steam flow at power station in Mexico ...

    To operate a large damper that controls the steam flow from a boiler into a steam turbine on a power station in Mexico. Products: ISC Hydraulic pump unit complete with programmed PLC. Our Brief: To design and build a modulating hydraulic actuator to operate the damper complete with a hydraulic control system and programmable PLC. The damper ...

    Get Price
  • Oxygen Control

    For O2 Trim Systems, 600 HP to 100,000 lbs per hour boilers, the investment costs are: Equipment: Controller in cabinet, pressure transmitter, O2 analyzer, flue gas temperature sensor, actuators for fuel valves (2) and FD damper. Equipment cost range is 11,000 …

    Get Price
  • Burnham PIN5SNI-ME2 Pkg, Steam, Nat, Ei Pse802 Lwco,

    The Independence is a residential, gas-fired boiler for steam systems It is available for either natural or LP gas and has AFUE ratings of up to 82% Its large water volume and durable cast iron sections make it an ideal replacement for even the most challenging steam …

    Get Price
  • KVS Valves Myanmar Co.,Ltd - Home

    KVS VALVES Myanmar Co., Ltd provide an extensive range of valves and deliver dedicated services and targeted solutions to our valued clientele. Accredited by international testing labs, KVS VALVES demonstrates a strong commitment by offering quality products. KVS Valves Myanmar Company is a one stop solution for HVAC product for Myanmar Market.

    Get Price
  • Spirax Sarco Myanmar

    Steam trapping solutions that effectively remove condensate will improve operating efficiency, safety and reduce energy costs in your steam system. Compressed Air Products Ensure air is delivered to the point of use at the right quantity and quality.

    Get Price
  • EG-30 thru -75 PEG-30 thru -65 - Weil-McLain

    2020-5-20 · EG-75 steam boilers with float-type low water cutoff EG-30 thru -65 steam boilers with float-type low water cutoff Control installation continued 1. Mount and wire controls per wiring diagram, page ... one boiler and so damper blade indicator is visible to the user. See Figure 8. 2. Screws or rivets used to secure the vent damper to

    Get Price
  • PB TYPE MARINE BOILER

    2020-8-6 · MARINE BOILER 1. Dimension : Boiler body (Excluding insulation) 2. Dry weight : Boiler body (Excluding water) 3. Working pressure : Accroding to requirement 4. Dimension(W) : Steam drum length 5. For other capacities, please contact us Steam Capacity Working pressure Dry weight (ton/hr) (kg/cm2) LW H (ton) PD01 25 16/22 3,960 3,900 6,950 36.8

    Get Price
  • BOILER (BABCOCK & WILCOX BOILER

    2017-2-22 · The Babcock and Wilcox Boiler consists of 1. Steam and water drum (boiler shell) 2. Water tubes 3. Uptake-header and down corner 4. Grate 5. Furnace 6. Baffles 7. Super heater 8. Mud box 9. Inspection door 10. Damper Steam and water drum (boiler shell): One half of the drum which is horizontal is filled up with water and steam remains on the ...

    Get Price
  • Boiler Cleaning Technology - Babcock & Wilcox

    B&W Diamond Power boiler cleaning systems are available in steam/air, high pressure water, and dual-media air heater cleaning configurations. With more than a century of experience in boiler cleaning, you can depend on low maintenance, reliability, …

    Get Price
  • BOILER : MAC-B - MITSUBISHI HEAVY INDUSTRIES - Ship ...

    -Boiler Mode Boiler Mode Condition Tanker Service COPT operation ECO Back up Exh. Eco. Back up during voyage IGS Top Up IGS Topping-up Repose (interlock with soot blower) Cancel unnecessary alarm while Boiler Stops Steam Press. 16k Burner Auto Start/Stop 12k/16.5k (1.57MPa) (1.18/1.62MPa) 6k 5.5k/7k (0.59MPa) (0.54/0.69MPa) - N/A - N/A -Automatic Operation Start : Steam Press. 12k …

    Get Price
  • KVS Valves Myanmar Co.,Ltd - Home

    KVS VALVES Myanmar Co., Ltd provide an extensive range of valves and deliver dedicated services and targeted solutions to our valued clientele. Accredited by international testing labs, KVS VALVES demonstrates a strong commitment by offering quality products. KVS Valves Myanmar Company is a one stop solution for HVAC product for Myanmar Market.

    Get Price
  • Damper drives for boilers - esmagazine.com

    2010-1-28 · Highly illustrated eight-page color brochure from ABB Instrumentation covers damper drive solutions for improved boiler control. According to the brochure, the average power plant has hundreds of actuators controlling airflow and other process variables to maximize the combustion process and minimize emissions.

    Get Price
  • Boiler damper not opening - Ask Me Help Desk

    My boiler flue damper is not opening and the unit will not start up. I do not believe it is the thermostat because I have tried three different thermostats and none correct the problem. I also tried bypassing the thermostat by connecting the red and white wires. The boiler still won't light. I noticed that when the thermostat calls for heat, the damper as not opening, so I figured a bad damper ...

    Get Price
  • Boiler Safety Devices – Operation Checklist

    2020-6-1 · boiler safety, safety devices, operations checklist, igniter, boiler safety devices, checklist, cutoff, gas, oil Description: This is a checklist used to review a VAMC's boiler safety devices. Last modified by: Bunn, Elizabeth (CFM) Created Date: 2/8/2002 6:13:00 PM Company: DVA Other titles: Boiler Safety Devices – Operation Checklist

    Get Price
  • Application Note: Flue Gas Analysis as a Boiler Diagnostic ...

    2020-3-28 · making fan or damper adjustments small enough to control at these low levels is difficult. Many operators will make manual adjustments based upon the CO signal, or use the measurement as a feed forward signal to adjust the O 2 control setpoint upwards or downwards. 16 Original Setpoint New Setpoint Actual Data % Excess O 2 % Steam Flow 14 12 10 ...

    Get Price
  • BOILER CONTROLS &BOILER CONTROLS &

    2010-11-15 · cylinder of the id fan damper to open orcylinder of the id fan damper to open or close the same and thus controls the ... technologies private limitedlimited 15. combustion control the steam demand from boiler varythe steam demand from boiler vary depending upon change in process requirement or power requirement. the fuel fed to the boiler ...

    Get Price
  • UH16 Series Gas Fired Steam Boilers

    2019-4-4 · Boiler is designed for use in closed heating systems where all steam is returned as condensate and make-up water is minimal. Boiler is not designed for or intended for use in open systems using 100% make-up water. Prior to Installation • Verify correct boiler for type of gas being used natural or propane. See Rating Plate.

    Get Price
  • Loud pop before the damper kicks in (steam boiler ...

    2019-11-13 · I just had a new Burnham Independence IN5I 140,000 (KIN-5) steam boiler installed. It has been running for 6 weeks. Before the damper kicks in and the the boiler fires up, there is a loud pop. It sounds like a bit like a balloon popping and is immediately followed by the squeaking of the damper. It doesn't happen every time the boiler fires up.

    Get Price
  • Boiler glossary, DAMPER to DUMP CONDENSER

    2021-6-12 · DAMPER-- An adjustable iron plate or shutter fitted across a boiler flue to regulate the draught.Often provided with an automatic electro-mechanical device that closes the damper to prevent heat from escaping through the funnel during burner stop periods.

    Get Price
  • Damper drives for boilers - esmagazine.com

    2010-1-28 · Damper drives for boilers. January 28, 2010. Order Reprints No Comments Highly illustrated eight-page color brochure from ABB Instrumentation covers damper drive solutions for improved boiler control. According to the brochure, the average power plant has hundreds of actuators controlling airflow and other process variables to maximize the ...

    Get Price
  • 1 THE BURMA STEAM-BOILERS AND PRIME MOVERS

    2019-3-9 · 06 Burma Steam-boilers and Prime-movers. [1882: Act XVIII. Coni-ience- (2) It shall, except where it is otherwise expressed, come into force on such day as the 1 Chief Commissioner of 2 British Burma, with the previous sanction of the Governor General in Council, may, by notifi­

    Get Price
  • Combined Cycle Power Plants - IMIA

    2020-12-17 · the 1950s and 1960s included conventional, fully-fired boilers. These systems were basically adaptations of conventional steam plants with the gas turbine exhaust gas serving as combustion air for the boiler. The efficiency of this type of combined cycle was approximately 5% to 6% higher than that of a similar conventional steam plant.

    Get Price
  • Dampers

    2006-12-1 · And if a natural drought boiler runs on top level power/steam output, and a fire like hell is on the firebars kept alive, the dampers fully open to permit maximum air flow in the furnace area to best combustion, if now a fireman stops ffeeding coal and drops suddenly the dampers, the drought will be cut off, because of less air will enter the ...

    Get Price
  • DIFFERENT METHODS OF STEAM TEMPERATURE

    2018-4-18 · POWER PLANT BOILER STEAM DRUM INTERNALS; According to the desired temperature at certain load, damper is set at certain position. The damper has to operate at high temperature and environment. So high temperature corrosion, erosion and failure may be take place. Draft loss in flue gas path is not always constant in this case.

    Get Price