Cambodia gas split hot water boiler draft hood

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • MGC Series 3

    2021-8-15 · The MGC Series 3 is available in two sizes from 262 MBH to 299 MBH and is designed for chimney-vent applications. With an efficiency of 84.0% AFUE, the latest design features a Hydrolevel FuelSmart control that monitors water temperature and delays burner start until residual heat has been transferred to the system for maximum efficiency. An integral Draft Hood and Automatic Vent Damper ...

    Get Price
  • REPAIR PARTS AND OPTIONAL ACCESSORIES

    2020-7-30 · Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES Ordering Instructions ... Split 7/8', #2874 * Sensor, 24' * Sensor Clip * Low Volt Harness * Line Volt Harness ... 34620601 Draft Hood (045) 1 34620602 Draft Hood (070, 096)

    Get Price
  • Series 63 Series 64 - PB Heat: Peerless® Boilers

    2020-8-11 · Series 63 ™& Series 64 Boiler Features Gas-fired, Cast Iron Boilers for Natural or LP Gas Packaged or Knockdown, Hot Water or Steam Boilers 13 Sizes, 3–12 Sections; Residential and Commercial Natural Draft (Chimney) Venting Up to 83.5% AFUE* Spark Ignition Large Water Content —Ideal for Steam and Large Volume Hot Water Applications

    Get Price
  • REPAIR PARTS AND OPTIONAL ACCESSORIES

    2021-2-2 · Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES ... Jacket, Flue and Draft Hood 3 Manifold Assembly & Gas Valve 4,5 Control Panel 6 Parts Box 8 Heat Exchanger & Insulation 10 ... NS 240006221 Heyco Split Ring Bushing for GV Harness 1

    Get Price
  • Gas-Fired Boilers

    The lowest efficiency boilers are atmospherically vented, Category I boilers. A Category I boiler operates with the flue at negative pressure with respect to the combustion appliance zone (CAZ), i.e., the room in which the boiler is located, and the stack temperature is above 140°F, which is hot enough to avoid condensation in the vent. The burner draws its combustion air from the CAZ.

    Get Price
  • Draft hood Definition

    Draft Hood. definition. Draft Hood means a component of gas- fired water heaters which mixes secondary air with the combustion gases leaving the unit thus enabling a smooth, continuous relief of gases up the vent pipe. Draft Hood means a device placed in and made a part of the flue pipe from an appliance, or a part of an appliance itself, which ...

    Get Price
  • Chimney Sizing

    2013-12-19 · Natural Gas Draft Hood 1.60 Natural Gas No Draft Hood 0.90 LP Gas Draft Hood 1.64 Oil All 1.24 Oil #2 Over 400,000 BTU/hr 0.85 Oil #6 Over 400,000 BTU/hr 0.86 Coal (Bituminous) All 1.54 Conversion Factors Table 5 BTU/hr Input = Boiler Horsepower @100% efficiency x 33475 “ Boiler Horsepower @ 80% efficiency x 42000

    Get Price
  • User’s Information Manual - Slant/Fin

    2020-4-29 · Figure 14. GG Series—Hot Water Boiler 4 Relief Valve ROLLOUT SAFETY SWITCH TEMPERATURE PRESSURE GAUGE GAS VALVE IGNITION CONTROL GAS MANIFOLD BURNERS SUPPLY VENT DAMPER DRAFT HOOD BLOCKED VENT SAFETY SWITCH PRESSURE RELIEF VALVE RETURN Location and identification of parts (Front panel removed) BRACKET FOR …

    Get Price
  • Boiler Repair & Replacement in Buffalo

    2021-8-19 · Radiators aren’t getting hot. Caused by sludge or air buildup in the system. Boiler keeps turning itself off. Could be caused by a number of issues: low water pressure, thermostat issue, closed valve causing low water flow, air or pump not circulating water properly. A lack of regular tune-ups can often contribute to boiler breakdowns.

    Get Price
  • The Function of a Draft Diverter

    A draft diverter, or draft hood, plays a vital role in the operation of a combustion chamber, such as a fireplace or furnace. The draft diverter, which consists of a baffle plate positioned directly above the primary flue, regulates the direction and amount of air flowing in and out of the burner.

    Get Price
  • WPSB Series 3

    2021-8-6 · Efficiency: Mid-Efficiency Capacity: Natural Gas (D Models): 75 - 112.5 - 150 - 187.5 - 225 - 262 - 299 MBH Propane (DP Models): 70 - 105 - 140 - 175 - 210 - 245 - 280 MBH; Heat Exchanger: Cast Iron Combustion: Atmospheric Venting: Chimney Vent Boiler Type: Hot Water Boiler Control Module: Fuel Smart Hydrostat Temperature Limit, LWCO and Boiler Reset Control with Circulator Relay and …

    Get Price
  • Chimney Sizing

    2013-12-19 · Natural Gas Draft Hood 1.60 Natural Gas No Draft Hood 0.90 LP Gas Draft Hood 1.64 Oil All 1.24 Oil #2 Over 400,000 BTU/hr 0.85 Oil #6 Over 400,000 BTU/hr 0.86 Coal (Bituminous) All 1.54 Conversion Factors Table 5 BTU/hr Input = Boiler Horsepower @100% efficiency x 33475 “ Boiler Horsepower @ 80% efficiency x 42000

    Get Price
  • High-Temperature Hot Water Supply - PHNIX E

    The HeatSpring Series can be operated for domestic hot water application in combination with various conventional boiler hot water systems like the gas boiler, coal boiler, and pellet boiler because the extended control system ensures that the heat pump unit is perfectly compatible with the existing boiler and works efficiently.

    Get Price
  • Utica Heating SW Series

    2021-8-20 · The Utica Heating SW Series Gas-Fired Water Boiler features a Honeywell High Limit/Electronic Ignition Control: Recessed under the boiler’s protective jacket Digital temperature display and diagnostics Plug in connection for the inducer fan Plug in connection for the system pump Control monitors the water temperature and delays the burner starting until residual heat has been transferred.

    Get Price
  • FSB Series 3

    2021-8-18 · The Pennco FSB Series 3 now features a Honeywell High Limit/Electronic Ignition Control. The control is recessed under the boiler's protective jacket and features a digital temperature display and diagnostics; plus a plug in connection for the inducer fan and a plug in connection for the system pump. This control monitors the water temperature and delays the burner starting until residual heat ...

    Get Price
  • Zhongshan Vangood Appliances Mfg Co., Ltd. - Gas Water ...

    Both our chief engineer for gas water heaters and chief engineer for gas hobs are from China top manufactures in this industry, Vanward and Chinabest. Zhongshan Vangood Appliances Mfg Co.,Ltd, have a strict quality system from the raw materials, the inspection and test control of each production process, final inspection and acceptance of the ...

    Get Price
  • Videos

    2021-8-22 · Boilers - Condensing Gas Boilers - Gas Boilers - Oil Indirect Hot Water Heaters Utica Heating. Research. Current Documents Archived Documents FAQ Rebates & Special Offers: Connect. Find A Dealer News Contact Customer Testimonials Give Feedback Warranty Registration Extended Warranties Careers. For Dealers. Dealer Portal Videos

    Get Price
  • Water Heater Backdrafting, Part 1 of 2: Why it Matters and ...

    2013-9-24 · An atmospherically vented water heater is a type with a draft hood, which relies on gravity to get the exhaust gases out of the home. Exhaust gas is hot and therefore lighter than the surrounding air, which is what allows it to rise up the vent …

    Get Price
  • DXL - Dunkirk

    2020-12-23 · GAS FIRED BOILERS . FOR FORCED HOT WATER With Hydrolevel Control. Models. DXL-060K DXL-095K. DXL-120K DXL-150K . DXL-175K DXL-205K. DXL-235K. Manufactured by: ECR International Inc. 2201 Dwyer Avenue, Utica, NY 13501 Tel. 800 253 7900 www.ecrinternational.com PN 240012803 REV. C [11/15/2020] Ordering Instructions. Order Parts through your ...

    Get Price
  • The Function of a Draft Diverter

    A draft diverter, or draft hood, plays a vital role in the operation of a combustion chamber, such as a fireplace or furnace. The draft diverter, which consists of a baffle plate positioned directly above the primary flue, regulates the direction and amount of air flowing in and out of the burner.

    Get Price
  • WPSB Series 3

    2021-8-6 · Efficiency: Mid-Efficiency Capacity: Natural Gas (D Models): 75 - 112.5 - 150 - 187.5 - 225 - 262 - 299 MBH Propane (DP Models): 70 - 105 - 140 - 175 - 210 - 245 - 280 MBH; Heat Exchanger: Cast Iron Combustion: Atmospheric Venting: Chimney Vent Boiler Type: Hot Water Boiler Control Module: Fuel Smart Hydrostat Temperature Limit, LWCO and Boiler Reset Control with Circulator Relay and …

    Get Price
  • Chimney Sizing

    2013-12-19 · Natural Gas Draft Hood 1.60 Natural Gas No Draft Hood 0.90 LP Gas Draft Hood 1.64 Oil All 1.24 Oil #2 Over 400,000 BTU/hr 0.85 Oil #6 Over 400,000 BTU/hr 0.86 Coal (Bituminous) All 1.54 Conversion Factors Table 5 BTU/hr Input = Boiler Horsepower @100% efficiency x 33475 “ Boiler Horsepower @ 80% efficiency x 42000

    Get Price
  • High-Temperature Hot Water Supply - PHNIX E

    The HeatSpring Series can be operated for domestic hot water application in combination with various conventional boiler hot water systems like the gas boiler, coal boiler, and pellet boiler because the extended control system ensures that the heat pump unit is perfectly compatible with the existing boiler and works efficiently.

    Get Price
  • Utica Heating SW Series

    2021-8-20 · The Utica Heating SW Series Gas-Fired Water Boiler features a Honeywell High Limit/Electronic Ignition Control: Recessed under the boiler’s protective jacket Digital temperature display and diagnostics Plug in connection for the inducer fan Plug in connection for the system pump Control monitors the water temperature and delays the burner starting until residual heat has been transferred.

    Get Price
  • FSB Series 3

    2021-8-18 · The Pennco FSB Series 3 now features a Honeywell High Limit/Electronic Ignition Control. The control is recessed under the boiler's protective jacket and features a digital temperature display and diagnostics; plus a plug in connection for the inducer fan and a plug in connection for the system pump. This control monitors the water temperature and delays the burner starting until residual heat ...

    Get Price
  • Zhongshan Vangood Appliances Mfg Co., Ltd. - Gas Water ...

    Both our chief engineer for gas water heaters and chief engineer for gas hobs are from China top manufactures in this industry, Vanward and Chinabest. Zhongshan Vangood Appliances Mfg Co.,Ltd, have a strict quality system from the raw materials, the inspection and test control of each production process, final inspection and acceptance of the ...

    Get Price
  • Videos

    2021-8-22 · Boilers - Condensing Gas Boilers - Gas Boilers - Oil Indirect Hot Water Heaters Utica Heating. Research. Current Documents Archived Documents FAQ Rebates & Special Offers: Connect. Find A Dealer News Contact Customer Testimonials Give Feedback Warranty Registration Extended Warranties Careers. For Dealers. Dealer Portal Videos

    Get Price
  • Water Heater Backdrafting, Part 1 of 2: Why it Matters and ...

    2013-9-24 · An atmospherically vented water heater is a type with a draft hood, which relies on gravity to get the exhaust gases out of the home. Exhaust gas is hot and therefore lighter than the surrounding air, which is what allows it to rise up the vent and out of the house.

    Get Price
  • DXL - Dunkirk

    2020-12-23 · GAS FIRED BOILERS . FOR FORCED HOT WATER With Hydrolevel Control. Models. DXL-060K DXL-095K. DXL-120K DXL-150K . DXL-175K DXL-205K. DXL-235K. Manufactured by: ECR International Inc. 2201 Dwyer Avenue, Utica, NY 13501 Tel. 800 253 7900 www.ecrinternational.com PN 240012803 REV. C [11/15/2020] Ordering Instructions. Order Parts through your ...

    Get Price
  • The Function of a Draft Diverter

    A draft diverter, or draft hood, plays a vital role in the operation of a combustion chamber, such as a fireplace or furnace. The draft diverter, which consists of a baffle plate positioned directly above the primary flue, regulates the direction and amount of air flowing in and out of the burner.

    Get Price
  • The Boiler Guy

    Make the Boiler Guy, Inc., your one stop shop for all your heating and air needs. We are fast efficient and make it our mission to listen to our customers in order to ensure 100% customer satisfaction. So, stop shopping around and call us today for your free estimate! We’d love the chance to earn your business.

    Get Price
  • Yankee Hood Drying Temperature Versus Impingement

    2019-9-20 · Hood contribution. Typical Energy Split • 40 to 50% Yankee cylinder • 50% to 60% Yankee hood Upper Limits Steel Yankee cylinders: • R w steam = ± 15 lbs H 2O/hr/ft2 High Temperature Yankee Hoods: • R. w. hood up to 30 lbs H. 2. O/hr/ft. 2 • The drying split becomes; • 66% hood 33% cylinder . Drying split: Yankee Cylinder vs ...

    Get Price
  • Technical Requirements for Plumbing Works in Buildings ...

    2018-3-16 ·  DRAW OFF POINTS - HOT WATER DRAW OFF POINT - COLD & HOT WATER DRAIN PIPE WITH PLUG O.F. OVERFLOW PIPE PUMP SET CALORIFIER [§] BOILER A4 210x297 PUMP SET OVERFLOW PIPE DRAIN PIPE WITH PLUG FLOAT SWITCH ...

    Get Price
  • XEB Series 3

    2021-8-15 · The XEB Series 3 Gas Fired Hot Water Boiler is available in 5 sizes from 42.5 MBH to 187.5 MBH with an AFUE of up to 84.4%. The XEB Series 3 features a Honeywell High Limit/Electronic Control. Recessed under the boiler's protective jacket; Digital temperature display and diagnostics; Plug in connection for the inducer fan

    Get Price
  • Gas Vent Pipe - Grainger Industrial Supply

    Gas vent pipe from Grainger, manufactured by reliable companies like Ameri-Vent and Bosch, comes in lengths of up to 4'L. These vent pipe kits include storm collar kits, vent adapters, connectors and elbows.

    Get Price
  • Venting Multiple Appliances Into A Common Chimney Or

    226.98. The flue piping of the system, whether for single or multiple appliances, should be as short a run as possible, and rise 1/4″ per running foot up and toward the chimney. Whenever possible, do not exceed 10 feet of flue pipe length. Avoid using more than …

    Get Price
  • 75,000 BTU 85% AFUE Laars Hot Water Gas Boiler -

    The boiler also has a draft damper to prevent your excessive gas leaking through the chimney instead of heating your home. The JVS series boilers have a 85% AFUE rating which means that for every every 1.00 you spend, 85 cents goes towards heating your home. Boiler Features. Hybrid Metal Heat Exchanger - The Mini-Therm uses a heat exchanger ...

    Get Price
  • Gas Tankless Water Heater Manuals

    2021-8-15 · Gas Tankless Water Heater Accessories Gas Conversion Kit (Greentherm 9000) Gas Conversion Kit (250SX 250SXO 2400E 2400EO 635ES 635ESO 715ES 2400ES 2700E Evolution 500 Integra 500 830ES 940ES 940ESO)

    Get Price
  • Official Website of SUNHOUSE Group - sunhouse

    Hot products. With a network of 50,000 points of sale, production and trading more than 450 groups of essential household products, SUNHOUSE products are present in the whole system of supermarkets, trade centers, traditional stores.

    Get Price
  • Hot Water Boilers

    Safe and efficient boilers for domestic or commercial heating and hot water supply purposes! Shop from WPS a wide array of top-quality hot water boilers.

    Get Price
  • Rangehood

    Rangehood, Ranges. La Germania N3602B 60cm Rangehood. 0 out of 5. (0) 3-speed push button control. 380 m³/h maximum air capacity. Washable aluminum filter. SKU: 108900160863. ₱ …

    Get Price
  • Boilers

    TBWES (a 100% subsidiary of Thermax Limited) is one of the foremost boiler manufacturers in the country, providing steam generation solutions for process and power needs. On offer are a range of options covering combustion of various solid, liquid and gaseous fuels, heat recovery from gas turbine engine exhaust, waste heat recovery and fired ...

    Get Price
  • Back to Basics: Venting for Gas-Fired Boilers

    2003-6-4 · All gas-fired, low pressure steam and hot water boilers certified to the ANSI Z21.13 standard are required to have the vent system category (I, II, III or IV) on the rating plate. The ANSI Z21.13 standard contains a uniform test procedure used to evaluate the vent system of all certified boilers…

    Get Price
  • Automatic Vent Damper System Gas Heat Quality Tips 101

    Automatic Vent Damper System | Gas Heat Flue Economizer. The automatic vent damper adds efficiency to water heaters and furnaces. The automatic flue damper traps heat in the furnace, boiler, or water heater. It holds heat in and around the heat exchanger …

    Get Price
  • Mechanical CAD Details

    2009-12-21 · hot water supply ~ j-i-----readfrom floor (range 0-200df) isolation gate /; ~.~.pipe union (typ)~old water supply valve(typ)~~ ~ t t electric water heater----~ n p&t relief valve f-----n (setting by mfr. of heater) cy--full size of valve outlet drain n fin.fl~o {route tempt. and press. valve <- outlet to 15 cm off floor or to floor drain when ...

    Get Price
  • CHAPTER 6. MECHANICAL SYSTEMS PERFORMANCE

    2017-8-31 · o Insulation of hot water and steam piping; o Boiler control from outdoor temperature; or o Other. 6-4. DOMESTIC HOT WATER. a. Systems. Domestic hot water heater systems shall have the capacity to maintain a minimum water temperature of l00F The maximum water temperature shall not exceed l20F at the tap for typical dwelling unit use.

    Get Price
  • Induced Draft - an overview

    2.07.2 Induced Draught Fans. An induced draught fan (ID fan) is provided to maintain a negative pressure in the furnace by sucking the products of combustion from it with a slight positive pressure at the discharge end vis-à-vis the bottom of the chimney/stack. This positive pressure, assisted by the stack effect of the heated chimney (∼120 ...

    Get Price
  • 2006 HHM FINAL - CDC

    2019-2-6 · Heating plant—The furnace, boiler, or the other heating devices used to generate steam, hot water, or hot air, which then is circulated through a distribution system. It typically uses coal, gas, oil or wood as its source of heat. Limit control—A thermostatic device installed in the duct system to shut off the supply of heat at a predetermined

    Get Price
  • Peerless 6409006 64-09 64 Series Semi-Commercial

    Peerless 6409006 64-09 64 Series Semi-Commercial Natural Gas Steam Boiler, 460,000 BTU, 82.5% AFUE, Natural DraftThe gas-fired, cast iron Series 64 boiler is an atmospheric, steam or hot water boiler with up to 83% combustion efficiency. The commercial boiler features an integral draft diverter for applications with space constraints and large boiler sections with high water …

    Get Price
  • How to Install a Boiler Vent Damper

    2010-2-16 · If you are interested in temperature control, find a boiler vent damper that offers this feature. Step 4 - Check Location of Damper. Check that the proposed location of the damper will be ok without being a danger. If there is any water source in line with the damper then you will need to check that it will actually be able to fit. Step 5 - Safety

    Get Price
  • History of Cambodia Constitution,Consultant History

    History Founded in 2009 in Phnom Penh, Cambodia, VRK CORPORATION CO., LTD is a design and build contractor for Mechanical, Electrical and Plumbing (MEP) system with Green Building Concept (LEED) projects of Commercial and Industrial Building food and beverages, chemicals, as well as high-rise buildings, etc. for which VRK provides engineering design services, supplies materials and …

    Get Price
  • Meyers Supply Company - Heating - JohnstownPA

    2013-10-14 · ARUBA 3 is CROWN's best selling gas-fired, hot water boiler. It comes in a wide range of sizes from 37,000 to 295,000 BTU/HR input. Crafted with a rugged, cast iron heat exchanger and stainless steel burners that are both backed by a lifetime limited warranty, the ARUBA 3 offers proven-in-service reliability, simplicity of design and economy in ...

    Get Price
  • N98-658

    Residential Gas Water Heater Power-Vent Water Heater. Gallons: 40; BtuH: 40,000; GPH Rec. 90°F Rise: 45; First Hour GPH: 73; Height with Draft Hood: 59'; Diameter ...

    Get Price
  • Mannix Heating & Air Conditioning Services

    Services. We work on any heating and cooling problem including emergency calls for your furnace, boiler, water heater, AC and Heat Pump. Service & Maintenance System Replacement Safety Inspections Services GasGas Fitting projects and gas leaks Water HeatersTank & Instant Water Heaters B ...

    Get Price
  • Induced Draft - an overview

    Swapan Basu, Ajay Kumar Debnath, in Power Plant Instrumentation and Control Handbook, 2015. 2.07.2 Induced Draught Fans. An induced draught fan (ID fan) is provided to maintain a negative pressure in the furnace by sucking the products of combustion from it with a slight positive pressure at the discharge end vis-à-vis the bottom of the chimney/stack.

    Get Price
  • Engineering Standards Manual: Standard Drawings & Details

    2004-9-30 · LANL Standard Drawings and Details either (1) depict required format/content or (2) are templates that are completed by a Design Agency (LANL or external AE) for a design drawing package, in a manner similar to specifications.

    Get Price
  • Residential Boilers Gas, Oil & Steam Boilers Carrier HVAC ...

    Shop for residential gas boilers from Carrier Enterprise (CE) - a globally trusted HVAC/R distribution company. ... Cast Orin Sections, Integral Draft, Field-Installed Draft Hood, Titanium Composite Burners, Insulated Casing, ... 80% AFUE 75000 Btuh Gas-Fired Hot Water Boiler . Item: BW3AAN000075 ...

    Get Price
  • USF BIM Equipment Asset Tags (USF-BIM-EA)

    2018-3-9 · IHWH 23-31 29 11 Instantaneous Hot Water Heaters. PLUM MS 23-31 13 19 17. Mop Sinks PLUM. PTD 23-31 25 19 11 Paper Towel Dispensers ... BDF 23-33 11 23 23 Boiler Draft Fans. HVAC Heating, Ventilation, and Air Conditioning Products and Equipment ... BFGHR 23-33 11 23 21 Boiler Fuel Gas Heat Recovery Devices BFOF 23-33 11 23 15 Boiler Fuel Oil ...

    Get Price
  • Commissioning - M&E Prefunctional Checklists

    2019-9-1 · Safety controls installed and safe operating ranges for this equipment provided to the commissioning agent Heating water piping and pump prefunctional checklists completed Boiler controls energized and safety controls tested Startup report includes optimal and actual percent CO2,CO, O2, stack temperature; combustion efficiency and NOX Specified ...

    Get Price
  • How to Install a Boiler Vent Damper

    2010-2-16 · If you are interested in temperature control, find a boiler vent damper that offers this feature. Step 4 - Check Location of Damper. Check that the proposed location of the damper will be ok without being a danger. If there is any water source in line with the damper then you will need to check that it will actually be able to fit. Step 5 - Safety

    Get Price
  • HVAC Inspection Guide - InterNACHI House of Horrors

    The return register at the duct to the left of the furnace and at the ceiling is within 10 feet of the draft hood of the water heater tank located in the same space as the return register. Return air openings should be located at least 10 feet in any direction from a combustion chamber or draft hood …

    Get Price
  • GAS SPILLAGE SENSING KIT - Field Controls

    2019-6-27 · 2. Block the flue pipe above the draft control, draft hood or draft diverter. 3. Re-establish gas supply to appliance and re-light pilot (if required). 4. Adjust thermostat to call for heat. 5. Flue gases should be emitting from draft control, draft diverter or draft hood. Note the location of the most flue gas …

    Get Price
  • LGB Boiler - Weil-McLain

    2020-5-20 · ' Horizontal collector hood installed. See page 15. 3. These parts may be on boiler: ' Supply and return piping installed. See pages 16 -20.' Gas control assembly' Compression tank piping' Pilot line tubing 4.These parts must be off boiler: ' Horizontal draft hood' Relief valves ' Combination Pressure-Temperature gauge' Steam or water gauges

    Get Price
  • Commissioning - M&E Prefunctional Checklists

    2019-9-1 · Safety controls installed and safe operating ranges for this equipment provided to the commissioning agent Heating water piping and pump prefunctional checklists completed Boiler controls energized and safety controls tested Startup report includes optimal and actual percent CO2,CO, O2, stack temperature; combustion efficiency and NOX Specified ...

    Get Price
  • GAS SPILLAGE SENSING KIT - InspectAPedia

    2019-1-4 · 2. Block the flue pipe above the draft control, draft hood or draft diverter. 3. Re-establish gas supply to appliance and re-light pilot (if required). 4. Adjust thermostat to call for heat. 5. Flue gases should be emitting from draft control, draft diverter or draft hood. Note the location of the most flue gas …

    Get Price
  • 2006 HHM FINAL - CDC

    2019-2-6 · Heating plant—The furnace, boiler, or the other heating devices used to generate steam, hot water, or hot air, which then is circulated through a distribution system. It typically uses coal, gas, oil or wood as its source of heat. Limit control—A thermostatic device installed in the duct system to shut off the supply of heat at a predetermined

    Get Price
  • Boilers

    Boilers deliver efficient, consistent warmth to the home without the noise and draft of forced air systems. FLAME installs two different types of Bryant series boilers. First and most efficient, is the Bryant Preferred™ Boilers. These boilers combine high-efficiency …

    Get Price
  • Reliance 40 Gallon Natural Gas Water Heater - 940NKCT

    2021-7-23 · Abt has special shipping on the Reliance 40 Gallon Tall Natural Gas Water Heater - 940NKCT. Buy from an authorized internet retailer and get free tech support for life.

    Get Price
  • Backdrafting Heating Equipment Hazards Guide

    Turn up the thermostat to turn on the boiler or furnace, and run hot water to turn on the water heater burner. Hold a smoke indicator, such as an incense stick, about 3 inches from the draft hood of a gas furnace or water hater or near the barometric damper of an oil furnace. Test a fireplace near the top center of the firebox opening, and a ...

    Get Price
  • How to Install a Boiler Vent Damper

    2010-2-16 · If you are interested in temperature control, find a boiler vent damper that offers this feature. Step 4 - Check Location of Damper. Check that the proposed location of the damper will be ok without being a danger. If there is any water source in line with the damper then you will need to check that it will actually be able to fit. Step 5 - Safety

    Get Price
  • GAS SPILLAGE SENSING KIT - Field Controls

    2019-6-27 · 2. Block the flue pipe above the draft control, draft hood or draft diverter. 3. Re-establish gas supply to appliance and re-light pilot (if required). 4. Adjust thermostat to call for heat. 5. Flue gases should be emitting from draft control, draft diverter or draft hood. Note the location of the most flue gas …

    Get Price
  • IDENTIFICATION FOR PIPING AND EQUIPMENT

    2011-6-14 · CH chiller GWH gas-fired water heater CHWP chilled water pump HTX heat exchanger CP condensate pump HWB hot water boiler CT cooling tower HWHP hot water heating pump CUH cabinet unit heater P pump (other than those listed) CWP condenser water pump RF return fan EWH electric water heater SB steam boiler FHEX fume hood exhaust fan SF supply fan ...

    Get Price
  • State GS6 40 BCS Proline Series 40 Gallon Natural Gas ...

    Air Eliminators Air Vents Baseboards Boilers & Boiler Parts Aquastats Backflow Preventers Boiler Drain Valves Boilers Expansion Tanks Hot Water Coils Ignition Transformers Low Water Cutoffs Mixing ... Height Including Draft Hood (inches) 51.5 Weight (pounds ) ... State GS6 40 BCS Proline Series 40 Gallon Natural Gas Water Heater Item SKU - GS6 ...

    Get Price
  • Automatic Vent Dampers

    Automatic Powered Vent Damper - When the thermostat calls for heat the powered automatic vent damper gets a signal to the motor to start turning the damper to the open position. As soon as the damper is open a switch closes that allows the burners to …

    Get Price
  • Utica 15B Series Gas-Fired Water Boiler

    By using similar materials instead of less expensive gaskets, or steel push nipples, the boiler maintains a water tight seal. Efficiency The 15B Series provides an annual fuel utilization efficiency of 82% as certified by the US Department of Energy.

    Get Price
  • PROLINE 40-GALLON PROPANE WATER HEATER

    The ProLine Series gas water heater is designed to deliver an economical performance that can lower your energy bills and also provide long-lasting value. Featuring a 30-gallon (nominal) tank and a 36,000 BTU propane burner, the GS6-30-ORBT (LP) Atmospheric Vent delivers a first hour rating of 80 gallons and a recovery rate of 36 gallons per hour.

    Get Price
  • ASHRAE Equipment Life Expectancy chart

    2021-6-18 · Boilers, hot water (steam) Steel water-tube 24 (30) Steel fire-tube 25 (25) Cast iron 35 (30) Electric 15 Burners 21 Furnaces Gas- or oil-fired 18 Unit heaters Gas or electric 13 Hot water or steam 20 Radiant Heaters Electric 10 Hot water or steam 25

    Get Price
  • Backdrafting Heating Equipment Hazards Guide

    Turn up the thermostat to turn on the boiler or furnace, and run hot water to turn on the water heater burner. Hold a smoke indicator, such as an incense stick, about 3 inches from the draft hood of a gas furnace or water hater or near the barometric damper of an oil furnace. Test a fireplace near the top center of the firebox opening, and a ...

    Get Price
  • Empire RH50C Closed Front Gas Room Heater - Natural

    Empire RH50C Closed Front Gas Room Heater - Natural Gas - RH-50CNAT This self-contained gas room heater by Empire features a closed front and is made to use with natural gas. This room heater efficiently warms large areas with 50,000 BTUs of …

    Get Price
  • NYC Department of Education - survey.nycsca.org

    2020-9-15 · DOMESTIC WATER SYSTEM Domestic Hot Water System Electric Domestic Water Heater Does not Exist Gas Fired Domestic Water Heater Inspected Instance Boiler Room Instance Condition 2 - Between Good and Fair Instance Quantity 1 Instance Quantity Uom EACH Instance Manufacturer A.O. Smith Equipment N/A Capacity/Size Quantity 75 Capacity/Size UOM MBH Input

    Get Price